This week, the group ran the first major temperature test for their top-level engineering requirement. The procedures for this test are given under 4.1.1 in the Acceptance Test Procedure. The results are given in the chart below.
![](https://static.wixstatic.com/media/f31638_02024bd2ac7248eb90dc504a02780dd0~mv2.png/v1/fill/w_690,h_426,al_c,q_85,enc_auto/f31638_02024bd2ac7248eb90dc504a02780dd0~mv2.png)
The maximum internal air temperature of the test vehicle occurred at 3:15 PM, reaching 95.3 °F. The maximum ambient air temperature for the day was 74 °F. The maximum internal air temperature was 128.8% of the outside maximum ambient temperature.
The results of the test indicate that the test vehicle's maximum internal air temperature does not exceed 130% of the maximum outside ambient temperature, which satisfies the group's top-level engineering requirement. Further testing will be conducted to verify the results.
The group also worked together to lay out the structure of the report.
Comments